Hikvision DS-UPS06K-R/TJL/IEC

SKU: 314001574

Thanks to online double conversion and power factor correction (PFC) technology, it achieves an input power factor of up to 0.99, resulting in high energy efficiency.

A digital control system ensures stable and reliable operation, while ECO mode optimizes energy consumption, reducing operating costs.

The UPS offers three-stage battery charging (constant current, constant voltage, and float), adapted to various operating conditions.

A wide input voltage range (110-300V) and frequency (40-70Hz) ensures compatibility with various power sources, including generators.

Comprehensive protection includes protection against overload, short circuit, overheating, low battery voltage, overcharge, and automatic diagnostics.

DS-UPS06K-R_TJL_IEC(314001574)_image_1

The output offers a pure sine wave (3:

 

DS-UPS06K-R_TJL_IEC(314001574)_image_2

1 crest factor), stable voltage (208/220/230/240V) and frequency (50/60Hz with auto-sensing).

VRLA batteries can be expanded with external battery packs, extending backup time. The UPS features an LCD display showing operating parameters and audible alarms for key events.

Efficiency in AC mode reaches 95% and in battery mode up to 93%. Its operating (0-40°C) and storage (-25-55°C) temperature ranges, along with low noise levels (≤50dB), make it ideal for commercial applications.

Dimensions of 440 x 621.5 x 86.5 mm and a weight of 15.5 kg, simplify installation. CE-LVD and CE-EMC certifications confirm compliance with safety and electromagnetic compatibility standards.

The Hikvision DS-UPS06K-R/TJL/IEC is a reliable solution for businesses and institutions requiring uninterrupted power supply.

Specification Hikvision DS-UPS06K-R/TJL/IEC

PowerUPS Capacity6000 VA / 6000 W
InputNominal Voltage208/220/230/240Vac
PhaseSingle Phase
Input Voltage Range110~300Vac (110~300Vac@50% load/176~300Vac@100% load)
Input Frequency40~70Hz (50/60Hz Auto-Sensing)
Power factor≥0.99
OutputOutput Voltage208/220/230/240Vac
Crest factor3:1
Power factor1
Output SocketsIEC version: Connecting terminal +IEC socket / US version: Connecting terminal+US socket panel
Output FrequencyOnline mode:±1%/±2%/±4%/±5%/±10% of the rated frequency (Optional) Battery mode: (50/60±0.1%)Hz
Harmonic distortion (THDv)≤1% Linear load / ≤3% Non linear load
Transfer TimeAC mode to Bat.mode: 0ms Inverter to Bypass: 0ms
Output WaveformPure Sinewave
BatteryBattery TypeValve Regulated Lead Acid (VRLA)
DC System Voltage (VDC)192/240Vdc (Settable)
Charging Current (Max.)12A
Expandable RuntimeYes, External battery pack: DS-UPSB09192A-R/TJ, or DS-UPSB09240A-R/TJ
Typical Backup TimeView Runtime Graph
IndicatorAlarmBattery mode/Battery low voltage/Overload/Fault
LCD displayInput voltage, Input frequency, Output voltage, Output frequency, Load percentage, Battery voltage, Inner temperature & Remaining battery backup time
EfficiencyAC ModeUp to 95%
Battery ModeUp to 93%
EnvironmentOperating Temperature0℃~40℃
Storage Temperature-25℃~55℃
Humidity Range0~95% (Non - condensing)
Altitude0~3000m (1000~3000m derating required)
Noise Level≤50dB
PhysicalDimension W x D x H (mm)440×621.5×86.5
Net weight (kg)15.5
StandardsSafetyCE-LVD IEC/EN 62040-1, IEC/EN 62477-1
EMCCE-EMC IEC/EN 62040-2 (IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8, IEC61000-4-11, IEC61000-2-2)

*We have done our best to provide an accurate description and specifications. Please note that these were created and translated automatically using manufacturer data. Colors and appearance may look different depending on your monitor settings. Before buying, please check the product sheet from the manufacturer for official information. The “Specification” section may refer to different variants of the same device (depending on the exact model name/identifier). If anything is unclear or inconsistent, please contact the seller before purchase. If warranty information is provided, it refers to the manufacturer’s warranty unless stated otherwise. Product images may show multiple color variants. If the model name does not include a color designation, it typically refers to the default version (e.g., for cameras: white). Other variants are indicated in the product name, such as “Black” or “BLK”.

Accessories Hikvision DS-UPS06K-R/TJL/IEC

DS-UPSB09192A-R_TJ(314001578)_image_1

DS-UPSB09192A-R/TJ

192Vdc, External battery pack for use with 6/10KVA UPS,with 16 PCS of 9Ah bu...

DS-UPSB09240A-R_TJ(314001579)_image_1

DS-UPSB09240A-R/TJ

240Vdc, External battery pack for use with 6/10KVA UPS,with 20 PCS of 9Ah bu...

DS-UPSTSF5K-R
R Series UPS Rack Slide 4-post

R_Series_UPS_SNMP_Card(314001589)_image_1

R Series UPS SNMP Card

Accessory: SNMP Card for remote communication • Supports SNMPv1/v2 and v3 pro...

Documents Hikvision DS-UPS06K-R/TJL/IEC

PDF
Datasheet_UPS6_10KVA_DS-UPSxxK-R_TJL_202504.pdf
PDF
Usermanual-6-10KVA-RACK-UPS-220_110V_US_ver_202601.pdf

Features

Features
Producer: HIKVISION