Description
XD-2 is a multipurpose wired detector, which can operate with any alarm control panel. XD-2 can work as: magnetic contact, shock detector, shock detector and magnetic contact, and water flood detector.
XD-2 can also work outdoors, even during adverse weather conditions, if placed inside the OPX-1 enclosure. When XD-2 is installed outside to work in one of the modes which require to use the magnet for proper operation, the OPXM-1 (magnet in a hermetic enclosure) must be used.
It is available in white (XD-2), brown (XD-2 BR) or dark grey (XD-2 DG).
- option to select detector type with DIP switches
- mode of operation:
- magnetic contact:
- detection of opening of a door, window, etc.
- input for connecting an NC type wired detector
- 1 alarm output
- shock detector:
- detection of shocks and vibrations accompanying attempts to force a door or window
- input for connecting an NC type wired detector
- 1 alarm output
- shock detector and magnetic contact
- detection of shocks and vibrations accompanying attempts to force open a door or window, etc.
- detection of opening a door, window, etc.
- input for connecting an NC type wired detector
- 1 or 2 alarm outputs
- water flood detector
- detection of flooding in rooms with plumbing
- input for connecting external flood probe FPX-1 (white), FPX-1 BR (brown) or FPX-1 DG (dark grey) - the probe available separately
- 1 alarm output
- magnetic contact:
- LED indicator
- remote enabling/disabling of LED indicator
- supply voltage control
- tamper protection against enclosure opening and removal from mounting surface
- 2 magnets included (for surface and flush mounting)
Specification
Magnet pad dimensions - recessed mounting | ø10 x 28 mm |
NC alarm outputs (NC relay, resistive load) | 40 mA / 24 V DC |
Detection range (depending on surface type) (shock detector) | up to 3 m |
SNS input sensitivity (flood probe) | 1 s |
SNS input sensitivity (NC type detector) | 150 ms |
Relay contact resistance (S alarm output) | 26 Ω |
Relay contact resistance (NC alarm output) | 26 Ω |
S alarm outputs (NC relay, resistive load) | 40 mA / 24 V DC |
Power supply voltage (±25%) | 12 V DC |
Tamper outputs (NC) | 40 mA / 24 V DC |
Maximum gap - recessed magnet (magnetic contact) | 19 mm |
Maximum gap - surface magnet (magnetic contact) | 15 mm |
Operating temperature range | -10°C...+55°C |
Magnet pad dimensions - surface mounting | 15 x 52 x 6 mm |
Magnet enclosure dimensions - surface mounting | 15 x 52 x 6 mm |
Security grade according to EN50131-2-6 | Grade 2 |
Complied with standards | EN 50130-4, EN 50130-5, EN 50131-1, EN 50131-2-6 |
Detector enclosure dimensions | 20 x 102 x 23 mm |
Environmental class according to EN50130-5 | II |
Maximum humidity | 93±3% |
Weight | 46 g |
Max. current consumption | 14 mA |
Standby mode current consumption | 12,5 mA |